null

Save BIG on Arrow Carports!

Typical Selkirk VP Pellet Pipe Installations

Jun 15th 2020

Typical Selkirk VP Pellet Pipe Installations

Selkirk gives you the safe, efficient, and cost-effective venting system that's engineered precisely for pellet burning stoves. Model VP Pellet Pipe has been tested and listed by Underwriters' Laboratories, Inc., in accordance with UL®-641 Standard for Low Temperature Venting Systems, as well as the applicable requirements from UL®-103 Standard for Residential Type and Building Heating Appliance Chimneys. VP Pellet Pipe, when installed according to Selkirk’s installation instructions, complies with National Safety Standards, such as NFPA -211. The system is rated for flue temperatures up to 570°F.

  • Available in 3" and 4" diameters
  • Full line of fittings and full range of pipe lengths increase installation flexibility
  • Proven coupling joint connects in seconds to assure joint integrity
  • Gasketed joint design
  • Double wall design with 1/4” airspace
  • Inner wall 304 stainless steel, outer wall paintable galvanized
  • Rolled-over male end eliminates sharp edges
  • 1" clearance to combustibles
  • Removable tee cap for inspection and cleaning
  • Internal spacing bead assures uniform insulating airspace between pipe walls

Horizontal Exit Termination

Horizontal Exit Termination

Through The Wall Installation

Through The Wall Installation

Horizontal Exit Termination

Through The Ceiling Rear Vent

Through The Wall Installation

Through The Wall Rear Vent

Minimum Clearance To Combustibles

Selkirk VP Pellet Pipe may be installed with a minimum 1" airspace clearance to combustible surfaces, such as framing lumber, drywall, plywood, or other building materials. VP Pellet Pipe may be exposed in occupied areas and painted pipe lengths help make your venting system an attractive accent to your interior decor. However, your venting system should be enclosed whenever it passes through closets, storage rooms, or accessible attics to ensure that the minimum 1” airspace clearance is maintained. This is particularly true in attics where cellulose-type or other blown-in Insulation materials could settle against the exposed vent pipe. It is also advisable to provide an enclosed chase for exterior vent systems to aid in reducing condensation and to protect the pipe from cold outdoor temperatures. VP Pellet Pipe features a proven joint design that allows for easy assembly. Special rope gaskets incorporated into the joint reduce leakage and help to minimize any accumulation of combustion powder residues. In addition, VP Pellet Pipe is listed for use with an optional, high-temperature silicon sealant which enhances the integrity of the joint assembly.